Property Address:
555 Sweet Street
Asheville, NC 28801
![]() |
![]() |
| Date: 10/19/2005 | Time: 12:14 PM | Report ID: Sample Two |
| Property: 555 Sweet Street Asheville, NC 28801 |
Customer: Ms. Yasmine Anderson |
Real Estate Professional: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Under 5 Years |
Client Is Present: No |
Radon Test: No |
| Water Test: No |
Weather: Clear |
Temperature: Over 60 |
| Rain in last 3 days: No |
![]() |
![]() |
| ROOF COVERING: ARCHITECTURAL |
VIEWED ROOF COVERING FROM: WALKED ROOF |
SKY LIGHT (S): TWO |
| CHIMNEY (exterior): ROCK WOOD |
| 1.0 | ROOF COVERINGS Comments: Repair or Replace |
||
![]() |
One ridge cap is cracked or
damaged at rear of home and may allow a leak to occur (Picture 1) .
There is one piece of a shingle that is missing near skylight
(Picture 2) .
|
| 1.1 | FLASHINGS Comments: Inspected |
| 1.2 | SKYLIGHTS, CHIMNEYS
AND ROOF PENETRATIONS Comments: Inspected |
| 1.3 | ROOFING DRAINAGE
SYSTEMS Comments: Inspected |
![]() |
![]() |
![]() |
![]() |
| SIDING STYLE: BATTEN |
SIDING MATERIAL: WOOD |
EXTERIOR ENTRY DOORS: WOOD STEEL |
| APPURTENANCE: BALCONY PATIO |
GARAGE DOOR MATERIAL: METAL |
GARAGE DOOR TYPE: TWO AUTOMATIC |
| DRIVEWAY: GRAVEL |
| 2.0 | WALL CLADDING
FLASHING AND TRIM Comments: Inspected |
| 2.1 | DOORS (Exterior) Comments: Repair or Replace |
|
![]() |
Two-door garage at left side
(facing front) has electronic sensors located higher than six inches
off floor which may not be installed according to manufacturers
specification. This could be considered unsafe and needs correcting.
Recommend a qualified contractor inspect and repair as needed.
|
| 2.2 | WINDOWS Comments: Repair or Replace |
|
![]() |
Vines need removing in order
to close green house window properly.
|
| 2.3 | GARAGE DOOR
OPERATORS (Report whether or not doors will reverse when met with
resistance) Comments: Repair or Replace |
|
![]() |
(1) Automatic opener for Garage door at left side (facing front) "left" door (from outside), will not reverse when met with resistance. This is considered unsafe and needs correcting. Recommend a qualified contractor inspect and repair as needed. | |
(2) A bumper guard installed
on wall is recommended to protect car from foundation wall in
garage.
|
| 2.4 | DECKS, BALCONIES,
STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS Comments: Inspected |
| 2.5 | VEGETATION,
GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS
(With respect to their effect on the condition of the building) Comments: Inspected |
||
![]() |
(1) Retaining wall appears
strong but a guardrail and pickets should be considered to prevent
children from accidental fall at driveway area and at rear of home
left of greenhouse (facing )rear.
|
||
![]() |
(2) Dirt bank at rear of
home is eroding. Two pits in ground exist and some form of ground
cover or landscaping is needed. Or perhaps drainage from gutter or
roof is spilling over in this area. I am unable to determine if this
has been corrected (no rain). Recommend a qualified contractor
inspect and perform the necessary repair.
|
| 2.6 | EAVES, SOFFITS AND
FASCIAS Comments: Inspected |
| 2.7 | OTHER Comments: Not Inspected |
|
![]() |
Waterfall was not on at rear
of home and I did not inspect piping or pump for proper operation.
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| CEILING MATERIALS: SHEETROCK |
WALL MATERIAL: SHEETROCK |
FLOOR COVERING(S): CARPET HARDWOOD T&G TILE |
| INTERIOR DOORS: SOLID RAISED PANEL |
WINDOW TYPES: THERMAL/INSULATED CASEMENT |
CABINETRY: WOOD VENEER |
| COUNTERTOP: GRANITE |
| 3.0 | CEILINGS Comments: Inspected |
| 3.1 | WALLS Comments: Inspected |
|
Tile surround at shower on
wall at floor junction has missing or loose grout in areas. Since
shower pan liner is not visible during an inspection, I cannot
determine if repairs are needed. Water can enter behind covering and
possibly damage framing if not corrected at Lower Level Bath at rear
of home. This is a small repair issue for your information.
Recommend a qualified contractor inspect and repair as needed.
|
| 3.2 | FLOORS Comments: Inspected |
|
Some scratches on flooring
in different areas of the home likely related to pets (FYI).
|
| 3.3 | STEPS, STAIRWAYS,
BALCONIES AND RAILINGS Comments: Inspected |
| 3.4 | COUNTERS AND A
REPRESENTATIVE NUMBER OF CABINETS Comments: Inspected |
| 3.5 | DOORS
(REPRESENTATIVE NUMBER) Comments: Inspected |
| 3.6 | WINDOWS
(REPRESENTATIVE NUMBER) Comments: Inspected |
| WATER SOURCE: WELL OR SPRING |
WATER FILTERS: SEDIMENT FILTER (We do not inspect filtration systems) |
PLUMBING SUPPLY: COPPER PVC |
| PLUMBING DISTRIBUTION: COPPER |
WASHER DRAIN SIZE: NOT VISIBLE |
PLUMBING WASTE: PVC |
| WATER HEATER POWER SOURCE: ELECTRIC PROPANE (QUICK RECOVERY) |
CAPACITY: 40 GAL (1-2 PEOPLE) 50 GAL (2-3 PEOPLE) |
MANUFACTURER: A.O. SMITH |
| 4.0 | INTERIOR DRAIN,
WASTE AND VENT SYSTEMS Comments: Not Inspected |
|
![]() |
Unused vent pipe in attic
(left after crawling in access) is unidentified. I am unable to
determine if this vent is connected to plumbing and therefore should
be vented out roof, Or is simply not used or connected. I recommend
a plumber inspect further and repair as needed.
|
| 4.1 | INTERIOR WATER
SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Comments: Not Inspected |
||
![]() |
(1) I did not test or
inspect the plumbing in greenhouse. I could not locate a heat source
for greenhouse and piping could freeze and damage could result if
not winterized each winter season.
|
||
![]() |
(2) I did not inspect the
well, pump or filtration systems. There is white deposits on shower
glass walls and shower head fixtures indicating hard water. I am
unable to determine if the filtration system includes treatment for
hard water. Recommend a plumber investigate further if desired.
|
||
| (3) FYI: When I ran hot water in master bath sinks it took longer than expected to get hot water. Supplemental hot water may be desired. | |||
(4) Jet powered tub worked
properly at time of inspection. I did not determine if jet powered
tub should've been installed in a bed of concrete or supported with
blocks. This tub was supported with blocks. Some manufacturers
require the tub to be installed in a bed of concrete to prevent
cracking or damage to the tubs finish. If interested, I recommend
obtaining the manual for your tub (Jacuzzi Brand) to determine if it
was installed according to manufacturer's specifications (Picture
3).
|
| 4.2 | HOT WATER SYSTEMS,
CONTROLS, CHIMNEYS, FLUES AND VENTS Comments: Inspected |
|
(Picture 1) Inspection view
|
| 4.3 | MAIN WATER SHUT-OFF
DEVICE (Describe location) Comments: Inspected |
|
The main shut off is the
green lever located in basement on front wall. This is for your
information.
|
| 4.4 | FUEL STORAGE AND
DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting,
supports, leaks) Comments: Inspected |
| 4.5 | SUMP PUMP Comments: Not Present |
| ELECTRICAL SERVICE
CONDUCTORS: BELOW GROUND ALUMINUM 220 VOLTS |
PANEL CAPACITY: 200 AMP (2) 200 AMP SERVICE PANEL |
PANEL TYPE: CIRCUIT BREAKERS |
| BRANCH WIRE 15 and 20 AMP: COPPER |
WIRING METHODS: ROMEX |
| 5.0 | SERVICE ENTRANCE
CONDUCTORS Comments: Inspected |
| 5.1 | SERVICE AND
GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION
PANELS Comments: Inspected |
| 5.2 | BRANCH CIRCUIT
CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE
AND VOLTAGE Comments: Inspected |
| 5.3 | CONNECTED DEVICES
AND FIXTURES (Observed from a representative number operation of
ceiling fans, lighting fixtures, switches and receptacles located
inside the house, garage, and on the dwelling's exterior walls) Comments: Repair or Replace |
||
![]() |
Three or more splice boxes
need coverplates within"Five feet" of attic access in attic (left
and right of access door). Electrical issues are considered a hazard
until repaired. Recommend a qualified licensed electrician correct.
|
| 5.4 | POLARITY AND
GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING
FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF
INSPECTED STRUCTURE Comments: Inspected |
| 5.5 | OPERATION OF GFCI
(GROUND FAULT CIRCUIT INTERRUPTERS) Comments: Inspected |
| 5.6 | LOCATION OF MAIN
AND DISTRIBUTION PANELS Comments: Inspected |
|
Main panel box is located at
both downstairs furnace rooms. However, main disconnect (shut-off)
is outside at meter base panel (for your information).
|
| 5.7 | SMOKE DETECTORS Comments: Inspected |
| 5.8 | OTHER Comments: Not Inspected |
|
![]() |
Back-up Generator was not
tested or inspected by me or my company. I recommend a qualified
licensed electrician inspect and operate. It is also recommended
that someone familiarize you with operating procedures in the event
of a power outage.
|
| FOUNDATION: POURED CONCRETE |
METHOD USED TO OBSERVE
CRAWLSPACE: WALKED |
FLOOR STRUCTURE: 2 X 10 WOOD JOISTS ENGINERED FLOOR TRUSS |
| WALL STRUCTURE: WOOD CONCRETE |
COLUMNS OR PIERS: WOOD PIERS CONCRETE PIERS |
CEILING STRUCTURE: 2X6 NOT VISIBLE |
| ROOF STRUCTURE: 2 X 8 RAFTERS PLYWOOD NOT VISIBLE |
ROOF-TYPE: GABLE |
METHOD USED TO OBSERVE
ATTIC: WALKED |
| ATTIC INFO: LIGHT IN ATTIC |
| 6.0 | FOUNDATIONS (Report
signs of abnormal or harmful water penetration into the building or
signs of abnormal or harmful condensation on building components.) Comments: Inspected |
| 6.1 | WALLS (Structural) Comments: Inspected |
| 6.2 | COLUMNS OR PIERS Comments: Inspected |
| 6.3 | FLOORS (Structural) Comments: Inspected |
| 6.4 | CEILINGS
(structural) Comments: Inspected |
| 6.5 | ROOF STRUCTURE AND
ATTIC Comments: Inspected |
| HEAT TYPE: FORCED AIR |
ENERGY SOURCE: PROPANE |
NUMBER OF HEAT SYSTEMS
(excluding wood): TWO |
| HEAT SYSTEM BRAND: CARRIER |
DUCTWORK: INSULATED |
FILTER TYPE: WASHABLE |
| TYPES OF FIREPLACES: CONVENTIONAL PROPANE GAS LOGS VENTED |
OPERABLE FIREPLACES: THREE |
NUMBER OF WOODSTOVES: NONE |
| 7.0 | HEATING EQUIPMENT Comments: Repair or Replace |
|
![]() |
Gas furnace appears to
operate properly but rust signs on housing indicates condensation
which may indicate poor venting. A more thorough inspection by a
qualified contractor is needed. Recommend further inspection by a
licensed HVAC contractor.
|
| 7.1 | NORMAL OPERATING
CONTROLS Comments: Inspected |
| 7.2 | AUTOMATIC SAFETY
CONTROLS Comments: Inspected |
| 7.3 | CHIMNEYS, FLUES AND
VENTS Comments: Not Inspected |
| Liner was partially visible and appeared good, but due to creosote build-up we could not inspect for cracks. Recommend a qualified chimney sweep clean and inspect for safety. |
| 7.4 | SOLID FUEL HEATING
DEVICES Comments: Inspected |
| 7.5 | HEAT DISTRIBUTION
SYSTEMS (including fans, pumps, ducts and piping, with supports,
insulation, air filters, registers, radiators, fan coil units and
convectors) Comments: Inspected |
||
Filter location both units
(see photo).
|
| 7.6 | GAS/LP FIRELOGS AND
FIREPLACES Comments: Repair or Replace |
|
![]() |
Damper lid for Vented fire
logs at kitchen is missing a clamp or lock that forces lid to stay
open (required for Vented Gas/LP logs). Without a clamp to force
open the damper, it could shut and cause unsafe carbon dioxide to
enter into living space. Recommend repair or replace as needed using
a qualified person.
|
| 7.7 | PRESENCE OF
INSTALLED HEAT SOURCE IN EACH ROOM Comments: Inspected |
| COOLING EQUIPMENT TYPE: AIR CONDITIONER UNIT |
COOLING EQUIPMENT ENERGY
SOURCE: ELECTRICITY |
CENTRAL AIR MANUFACTURER: CARRIER |
| NUMBER OF A/C UNITS: TWO |
| 8.0 | COOLING AND AIR
HANDLER EQUIPMENT Comments: Inspected |
||
![]() |
There are two small size air
conditioners that serve to cool the home. I am unable to determine
if these sizes are adequate to cool home or whether or not all areas
of home are cooled. Recommend a qualified licensed HVAC person
determine if these are adequate.
|
| 8.1 | NORMAL OPERATING
CONTROLS Comments: Inspected |
| 8.2 | DISTRIBUTION
SYSTEMS (including fans, pumps, ducts and piping, with supports,
insulation, air filters, registers, radiators, fan coil units and
convectors) Comments: Inspected |
| 8.3 | PRESENCE OF
INSTALLED COOLING SOURCE IN EACH ROOM Comments: Inspected |
| ATTIC INSULATION: BLOWN FIBERGLASS |
R- VALUE: R-30 OR BETTER |
VENTILATION: RIDGE VENTS SOFFIT VENTS |
| EXHAUST FAN TYPES: FAN/HEAT/LIGHT |
DRYER POWER SOURCE: 22O ELECTRIC |
DRYER VENT: FLEXIBLE METAL METAL |
| 9.0 | INSULATION AND
VAPOR RETARDERS (in unfinished spaces) Comments: Inspected |
| 9.1 | VENTILATION OF
ATTIC AND FOUNDATION AREAS Comments: Inspected |
| 9.2 | VENTING SYSTEMS
(Kitchens, baths and laundry) Comments: Inspected |
| 9.3 | VENTILATION FANS
AND THERMOSTATIC CONTROLS (ATTIC) Comments: Not Present |
| DISHWASHER: ASKO |
DISPOSER: IN SINK ERATOR |
EXHAUST/RANGE HOOD: BROAN |
| RANGE/OVEN: DAYCOR |
BUILT-IN MICROWAVE: KITCHEN AIDE |
TRASH COMPACTORS: NONE |
| REFRIGERATOR: SUB ZERO |
| 10.0 | DISHWASHER Comments: Inspected |
| 10.1 | RANGES/OVENS/COOKTOPS Comments: Inspected |
| 10.2 | RANGE HOOD Comments: Inspected |
| 10.3 | TRASH COMPACTOR Comments: Not Present |
| 10.4 | FOOD WASTE DISPOSER Comments: Inspected |
| Disposer power switch is too low, and does not prevent children from operating. |
| 10.5 | MICROWAVE COOKING
EQUIPMENT Comments: Inspected |
![]() HomeBuyers Inspection HBI 18 Business Park Circle |
|
Customer |
|
Property Address |
| 1.0 | ROOF COVERINGS | |
| Repair or Replace | ||
![]() |
One ridge cap is cracked or damaged at rear of home and may
allow a leak to occur (Picture 1) . There is one piece of a
shingle that is missing near skylight (Picture 2) .
|
|
| 2.1 | DOORS (Exterior) | |
| Repair or Replace | ||
![]() |
Two-door garage at left side (facing front) has electronic
sensors located higher than six inches off floor which may not
be installed according to manufacturers specification. This
could be considered unsafe and needs correcting. Recommend a
qualified contractor inspect and repair as needed.
|
|
| 2.2 | WINDOWS | |
| Repair or Replace | ||
![]() |
Vines need removing in order to close green house window
properly.
|
|
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) | |
| Repair or Replace | ||
![]() |
(1) Automatic opener for Garage door at left side (facing front)
"left" door (from outside), will not reverse when met with
resistance. This is considered unsafe and needs correcting.
Recommend a qualified contractor inspect and repair as needed.
|
|
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) | |
| Inspected | ||
![]() |
(1) Retaining wall appears strong but a guardrail and pickets
should be considered to prevent children from accidental fall at
driveway area and at rear of home left of greenhouse (facing
)rear.
|
|
![]() |
(2) Dirt bank at rear of home is eroding. Two pits in
ground exist and some form of ground cover or landscaping is
needed. Or perhaps drainage from gutter or roof is spilling over
in this area. I am unable to determine if this has been
corrected (no rain). Recommend a qualified contractor inspect
and perform the necessary repair.
|
|
| 2.7 | OTHER | |
| Not Inspected | ||
![]() |
Waterfall was not on at rear of home and I did not inspect
piping or pump for proper operation.
|
|
| 4.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | |
| Not Inspected | ||
![]() |
Unused vent pipe in attic (left after crawling in access) is
unidentified. I am unable to determine if this vent is connected
to plumbing and therefore should be vented out roof, Or is
simply not used or connected. I recommend a plumber inspect
further and repair as needed.
|
|
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | |
| Not Inspected | ||
![]() |
(1) I did not test or inspect the plumbing in greenhouse. I
could not locate a heat source for greenhouse and piping could
freeze and damage could result if not winterized each winter
season.
|
|
![]() |
(2) I did not inspect the well, pump or filtration systems.
There is white deposits on shower glass walls and shower head
fixtures indicating hard water. I am unable to determine if the
filtration system includes treatment for hard water. Recommend a
plumber investigate further if desired.
|
|
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | |
| Repair or Replace | ||
![]() |
Three or more splice boxes need coverplates within"Five feet" of
attic access in attic (left and right of access door).
Electrical issues are considered a hazard until repaired.
Recommend a qualified licensed electrician correct.
|
|
| 5.8 | OTHER | |
| Not Inspected | ||
![]() |
Back-up Generator was not tested or inspected by me or my
company. I recommend a qualified licensed electrician inspect
and operate. It is also recommended that someone familiarize you
with operating procedures in the event of a power outage.
|
|
| 7.0 | HEATING EQUIPMENT | |
| Repair or Replace | ||
![]() |
Gas furnace appears to operate properly but rust signs on
housing indicates condensation which may indicate poor venting.
A more thorough inspection by a qualified contractor is needed.
Recommend further inspection by a licensed HVAC contractor.
|
|
| 7.6 | GAS/LP FIRELOGS AND FIREPLACES | |
| Repair or Replace | ||
![]() |
Damper lid for Vented fire logs at kitchen is missing a clamp or
lock that forces lid to stay open (required for Vented Gas/LP
logs). Without a clamp to force open the damper, it could shut
and cause unsafe carbon dioxide to enter into living space.
Recommend repair or replace as needed using a qualified person.
|
|
| 8.0 | COOLING AND AIR HANDLER EQUIPMENT | |
| Inspected | ||
![]() |
There are two small size air conditioners that serve to cool the
home. I am unable to determine if these sizes are adequate to
cool home or whether or not all areas of home are cooled.
Recommend a qualified licensed HVAC person determine if these
are adequate.
|
|
Prepared Using HomeGauge
http://www.homegauge.com SHGI (c)